Received 20.10.2025

DOI: 10.35556/idr-2026-1(114)4-11

Assessing of the accuracy and reproducibility of dental Implant surgical guides manufactured by stereolithographic 3D printing
Losev F.F.1,2, ORCID: 0000-0002-9448-9614
Brailovskaya T.V.1,2, ORCID: 0000-0003-0407-0885
Sharganov A.F.1, ORCID: 0009-0000-7679-9777
1 National Medical Research Center for Dentistry and Maxillofacial Surgery of the Ministry of Health of Russia
119021, Russia, Moscow, Timura Frunze St., 16.
2 Federal State Autonomous Educational Institutionof Higher Education I.M. Sechenov First Moscow State Medical University of the Ministry of Healthcare of the Russian Federation
119048, Russia, Moscow, Trubetskaya St., 8, bld. 2

E-mail address: brailovskaya@cniis.ru

Summary
This article presents the results of a comparative analysis of the accuracy of dental implant surgical guides manufactured by stereolithography (SLA) with layer thicknesses of 0.05 mm and 0.1 mm.
The aim of the study was to evaluate the influence of printing resolution on the reproducibility of key geometric parameters: the diameter and height of the guide holes, the arch length, the height of the guide, and its wall thickness. The study was conducted on two series of five identical samples each using precision measuring instruments.
The results and discussion showed that the maximum deviations for all controlled parameters in both series were within clinically acceptable limits (up to 0.2 mm for linear dimensions and up to 3 mm for arch length). Reducing the layer thickness from 0.1 mm to 0.05 mm did not result in a statistically significant increase in accuracy, but it did contribute to greater stability in the guide channel diameters.
It was concluded that a 0.1 mm layer thickness can be used to manufacture surgical guides without compromising their accuracy, thereby optimizing production time and costs.

Keywords: surgical guide, 3D printing, stereolithography (SLA), dental implantation, additive manufacturing.

For citation: Losev F.F., Brailovskaya T.V., Sharganov A.F. Assessing the accuracy and reproducibility of dental implant surgical guides manufactured by stereolithographic 3d printing. Stomatology for All / Int. Dental Review. 2026; no. 1 (114): 4–11 (in Russian). doi: 10.35556/idr-2026-1(114)4-11

References
1. Bencharit S., Staffen A., Yeung M., Whitley D. 3rd., Laskin D.M., Deeb G.R. In Vivo Tooth-Supported Implant Surgical Guides Fabricated with Desktop Stereolithographic Printers: Fully Guided Surgery Is More Accurate Than Partially Guided Surgery. J Oral Maxillofac Surg. 2018; no. 76 (7): 1431–1439. doi: 10.1016/j.joms.2018.02.010
2. Bilhan H., Arat S., Mumcu E., Geckili O., Sakar O. Precision of implant placement with stereolithographic templates: a pilot in vitro study. J Oral Implantol. 2012; no. 38 (5): 569–74. doi: 10.1563/AAID-JOI-D-10-00109
3. Dandekeri S., Sowmya M.K., Bhandary S. Stereolithographic Surgical Template: A Review. J Clin Diagn Res. 2013; no. 7 (9): 2093–2095
4. Herschdorfer L., Negreiros W., Gallucci G., Hamilton A. Comparison of the accuracy of implants placed with CAD-CAM surgical templates manufactured with various 3D printers: An in vitro study. J Prosthet Dent. 2021; no. 125 (6): 905–910.
5. Jan D’haese., Komiyama A., Hultin M., De Bruyn H. Accuracy and Complications Using Computer-Designed Stereolithographic Surgical Guides for Oral Rehabilitation by Means of Dental Implants: A Review of the Literature. Clin Implant Dent Relat Res. 2012; no. 14 (3): 321–335.
6. Kiatkroekkrai P., Takolpuckdee C., Subbalekha K., Mattheos N., Pimkhaokham A. Accuracy of implant position when placed using static computer-assisted implant surgical guides manufactured with two different optical scanning techniques: A randomized clinical trial. Int J Oral Maxillofac Surg. 2020; no. 49 (3): 377–383.
7. Lal K., White G., Morea D., Wright R. Use of Stereolithographic Templates for Surgical and Prosthodontic Implant Planning and Placement. Part I. The Concept. J Prosthodont. 2006; no. 15 (1): 51–58.
8. Lan D., Luo Y., Qu Y., Man Y. The three-dimensional stability and accuracy of 3D printing surgical templates: An In Vitro study. J Dent. 2024; no. 144: 104936. doi: 10.1016/j.jdent.2024.104936
9. Marei H.F., Alshaia A., Alarifi S., Almasoud N., Abdelhady A. Effect of steam heat sterilization on the accuracy of 3D printed surgical guides. Implant Dent. 2019; no. 28 (4): 372–377.
10. Scherer U., Stoetzer M., Ruecker M., Gellrich N.C., von See C. Template-guided vs. non-guided drilling in site preparation of dental implants. Clin Oral Investig. 2015; no. 19 (6): 1339–1346.
11. Schneider D., Marquardt P., Zwahlen M., Jung R.E. A systematic review on the accuracy and the clinical outcome of computer guided template-based implant dentistry. Clin Oral Implants Res. 2009; 20, no. 4, p. 73–86.
12. Sommacal B., Savic M., Filippi A., Kuhl S., Thieinger F. Evaluation of Two 3D Printers for Guided Implant Surgery. Int J Oral Maxillofac Implants. 2018; 33 (4): 743–746.
13. Sun Y., Luebbers H., Agbaje J., Schepers S., Politis C., Slycke S., Vrielinck L. Accuracy of Dental Implant Placement Using CBCT-Derived Mucosa-Supported Stereolithographic Template. Clin Implant Dent Relat Res. 2015; no. 17 (5): 862–870.
14. Tallarico M., Kim Y.J., Cocchi F., Martinolli M., Meloni S.M. Accuracy of computer-assisted template-based implant placement using two different surgical templates designed with or without metallic sleeves: A randomized controlled trial. Dent J (Basel). 2019; no. 7 (3): 41.
15. Kostin K.A., Kozhevin M.V., Erohin M.A., Ponomarev O.Yu. On the features of the use of digital technologies in the planning and implementation of orthopedic treatment using dental implants. Stomatology for All / Int. Dental Review. 2019; no. 3 (88); 42–46 (in Russian). doi: 10.35556/idr-2019-3(88)42-46
16. Van Assche N., Vercruyssen M., Coucke W., Teughels W., Jacobs R., Quirynen M. Accuracy of computer-aided implant placement. Clin Oral Implants Res. 2012; 23, 6, p. 112–123.

Яндекс.Метрика