Received 28.02.2025

DOI: 10.35556/idr-2025-2(111)10-14

Comparative analysis of modern methods of dental implant surface modification

Eshkulov U.E.1, SPIN-код: 4563-6100, ORCID: 0000-0002-0238-0313, AuthorID: 1203015
Ivanov S.Yu.2,3, SPIN-код: 2607-2679, ORCID: 0000-0001-5458-0192, AuthorID: 615227
Kucherova A.V.2, SPIN-код: 8570-8494, ORCID: 0009-0005-3872-552X, AuthorID: 1231222
Tarbokov V.A.4, SPIN-код: 6043-8895, ORCID: 0000-0001-9366-5965, AuthorID: 138693
1 ООО «Stomatologiya doctora Alimbekova», 117449, Moscow, Vinokurova str, 2
2 Patrice Lumumba PFUR, Department of Oral and Maxillofacial Surgery and Surgical Dentistry, 117198, Moscow, Miklukho-Maklaya str., 6
117198, Russia, Moscow, str. Miklukho-Maklaya, 10
3 I.M. Sechenov First Moscow State Medical University, Ministry of Health of Russia
119991, Moscow, Trubetskaya st., 8/2
4 Federal state autonomous educational institution “National research Tomsk Polytechnic University”.
634050, Russia, Tomsk, Lenin Avenue, 30

E-mail address: urmatbiy@gmail.com

Summary
In the article a comparative analysis of the results of modification of dental implants (DI) surfaces treated by a complex method using sandblasting (SB) and high-power ion beam (HPIB) treatment is carried out.
The samples of Russian-made IRIS DIs after SB and HPIB processing, as well as foreign DIs Astra and Zimmer were investigated.
Micro-images of DI surfaces and data on their chemical composition on the basis of spectral analysis (SA), as well as data on the migration of impurities through the surfaces of titanium alloys were obtained.
Conclusions are made about the changes that have taken place in the samples as a result of their processing by the method under consideration, as well as about the prospects of the complex technology, including SB and HPIB processing, in the development of new materials for DI.

Keywords: dental implant, powerful ion beam, osseointegration, spectrometry.
For citation: Eshkulov U.E., Ivanov S.Yu., Kucherova A.V., Tarbokov V.A. Comparative analysis of modern methods of dental implant surface modification. Stomatology for All / Int. Dental Review. 2025; no. 2 (111): 10–14 (in Russian). doi: 10.35556/idr-2025-2(111)10-14

References
1. Buyukguclu G., Ozkurt-Kayahan Z., Kazazoglu E. Reliability of the Osstell Implant Stability Quotient and Penguin Resonance Frequency Analysis to Evaluate Implant Stability. Implant Dent. 2018; no. 27 (4): 429–433. doi: 10.1097/ID.0000000000000766
2. Sidelnikov A.I. Comparative characteristic of the materials of titanium group used in the production of modern dental implants. Infodent. 2000; no. 5: 10–12 (in Russian).
3.BusinesStat. Analysis of the market of implants for dentistry in Russia in 2019–2023, forecast for 2024–2028. 13 p. (in Russian).
4. Fedchishin O.V., Ushakov R.V. Experimental evaluation of the effectiveness of domestic russian implants with modified surface. Stomatology for All / Int. Dental Review. 2024; no. 1 (106): 16–20 (in Russian). doi: 10.35556/idr-2024-1(106)16-20
5. Tarbokov V.A., Pavlov S.K., Remnev G.E. et al. Complex surface modification of titanium alloys. Springer. 2018; no. 11: 80–84 (in Russia).
6. Schunemann F.H., Galarraga-Vinueza M.E., Magini R., Fredel M., Silva F., Souza J.C.M. et al. Zirconia surface modifications for implant dentistry. Mater Sci Eng C Mater Biol Appl. 2019; no. 98: 1294–1305. doi: 10.1016/j.msec.2019.01.062
7. Dolgalev A.A., Muraev A.A., Lyakhov P.A., Lyakhova U.A., Choniashvili D.Z., Zolotaev K.E., Semerikov D.Y., Avanisyan V.M. Architectonics of Artificial Intelligence System and Prospects of Application of Machine Learning Technologies in Stomatology. Literature review. Chief physician of the South of Russia. 2022; no. 5 (86): 2–6 (in Russia).
8. Eshkulov U.E., Ivanov S.Yu., Tarbokov V.A., Volkov A.V., Dymnikov A.B., Shaykhaliev A.I., Kulnazarov A.S. Micro-X-ray spectral analysis and in vivo study of complex-modified titanium implants. Bulletin of Experimental Biology and Medicine. 2022; 173, no. 4: 516–521 (in Russia). doi: 10.47056/0365-9615-2022-173-4-516-521
9. Eshkulov U.E., Tarbokov V.A., Ivanov S.Y., Nochov-naya N.A., Dymnikov A.D., Alymbaev R.S. In vitro study of biocompatibility of titanium alloys with modified surface. Journal Biomed. 2021; 17, no. 2: 79–87 (in Russia). doi: 10.33647/2074-5982-17-2-79-87
10. Kulakov A.A., Badalyan V.A., Parinov D.A., Martiro-sova A.Yu. Modern approaches of the soft tissues volume increase in the area of teeth and implants with the use of connective tissue autografts. International journal of applied and fundamental research. 2020; no. 2: 69–73 (in Russia). doi: 10.17513/mjpfi.13012
11. Quesada-García M.P, Prados-Sanchez E., Olmedo-Gaya M.V., Munoz-Soto E., Gonzalez-Rodríguez M.P., Valllecillo-Capilla M. Measurement of dental implant stability by resonance frequency analysis: a review of the literature. Med Oral Patol Oral Cir Bucal. 2009; no. 14 (10): 538–546. doi: 10.4317/medoral.14.e538. PMID: 19680211
12. Mironov M.M., Grebenshchikova M.M., Starodumova E.V. Investigation of metal ion migration from protective nanostructured coatings for im-plants. Herald of technological university. 2016; no. 19 (20): 23–26 (in Russia).
13. Muraev A.A., Ivanov S.Y., Leonov S.V., Mroue A.H., Mukhametshin R.F., Gazhva Y.V. Comparative analysis of biomechanics at different nodes of implant and abutment conjugation on the basis of the data of three-dimensional finite element modeling. Stomatology. 2019; 98, no. 1: 11–16 (in Russia). doi: 10.17116/stomat20199801111
14. Muraev A.A., Murzabekov A.I., Ivanov S.Y., Tarasov Y.V., Orlov E.A., Dolgalev A.A. Modification of the dental implants surface by means of plasma electrolytic oxidation. Modern technologies in medicine. 2023; 15, no. 3: 18–25 (in Russia). doi: 10.17691/stm2023.15.3.02
15. Nalchajyan A.M., Muraev A.A., Bophoev S.V., Ghazaryan G.G., Tunyan G.D., Martirosyan M.P. Directed bone regeneration of the alveolar part of the mandible with the use of individualized titanium frame membrane: a clinical case. Clinical Dentistry. 2024; no. 26 (4): 29–33 (in Russia). doi: 10.37988/1811-153X_2023_4_29
16. Chuiko A.N., Surov O.N., Shinchukovsky I.A., Alym-Baev R.S. About features of biomechanics at fixation of subperiosteal implants. Ukrainian stomatologic almanac. 2010; no. 1: 27–38 (in Russia).

Яндекс.Метрика